Heavy Metals Panel (ICP-MS)
Ultra-Trace Elemental Impurities Quantification for Toxic Heavy Metals (Lead, Arsenic, Cadmium, Mercury) with Parts-Per-Billion (ppb) Sensitivity using Inductively Coupled Plasma Mass Spectrometry.
Why Heavy Metals Testing is Mandatory for Purity
Heavy metal contamination in peptides, raw APIs, and chemical syntheses originates from transition metal catalysts (e.g. palladium, platinum, ruthenium), mineral reagents, contaminated process water, or substandard glassware during manufacturing. Even microscopic trace amounts present severe bio-accumulation toxicity risks.
At Zenith BioChemical Laboratories HK, elemental impurity screening is performed using our Agilent 7900 ICP-MS with an Octopole Reaction System (ORS4) operating in helium collision cell mode to eliminate polyatomic spectral interferences (such as 40Ar35Cl+ on 75As). Prior to plasma ionization, samples undergo closed-vessel microwave digestion in high-purity sub-boiled nitric acid (HNO3), completely digesting the organic matrix while preventing the loss of volatile elements such as mercury.
Core Heavy Metals Screened
Strict compliance with USP <232> and ICH Q3D Permitted Daily Exposure (PDE) limits.
Lead (Pb) • Mass 206/207/208
Neurotoxic heavy metal accumulating in bone and organs. Quantified down to 0.5 ppb with strict pharmacopeial threshold limits (< 0.5 ppm).
Arsenic (As) • Mass 75
Potent cellular toxin and enzyme inhibitor. Helium collision mode completely resolves argon chloride interferences for absolute accuracy.
Cadmium (Cd) • Mass 111/114
Nephrotoxic and osteotoxic element. Measured against multi-element NIST traceable reference calibration curves.
Mercury (Hg) • Mass 200/202
Volatile organic and inorganic neurotoxin. Stabilized with gold (Au) spikes during microwave digestion to prevent volatilization loss.
USP <232> / ICH Q3D Threshold Specifications
| Element | USP <232> Parenteral Limit | Zenith Method LOD | Standard Status |
|---|---|---|---|
| Lead (Pb) | ≤ 0.5 ppm (μg/g) | 0.002 ppm (2.0 ppb) | Conforms to USP <232> |
| Arsenic (As) | ≤ 1.5 ppm (μg/g) | 0.005 ppm (5.0 ppb) | Conforms to USP <232> |
| Cadmium (Cd) | ≤ 0.5 ppm (μg/g) | 0.001 ppm (1.0 ppb) | Conforms to USP <232> |
| Mercury (Hg) | ≤ 0.3 ppm (μg/g) | 0.002 ppm (2.0 ppb) | Conforms to USP <232> |
| Nickel (Ni) | ≤ 20.0 ppm (μg/g) | 0.010 ppm (10.0 ppb) | Conforms to ICH Q3D |
Submission Guidelines for ICP-MS
- Sample Quantity: 20 – 50 mg dry powder or 1.0 mL liquid in metal-free polypropylene or PTFE vials.
- Container: Avoid metal caps or unlined glass containers that could leach trace elements.
- Destructive Testing: Samples are fully consumed by microwave acid digestion.
- Reporting: Comprehensive report with parts-per-billion (ppb) and parts-per-million (ppm) quantitation tables.